Sign In | Join Free | My benadorassociates.com
China Henan Lanphan Industry Co.,Ltd logo
Henan Lanphan Industry Co.,Ltd
We adhere to the concept “loyal, responsible, being professional ” and stimulate all the staff to be of one heart and one mind, work with collective wisdom and concerted efforts, in order to provide
Verified Supplier

5 Years

Home > Chiller Lab Equipment >

Glycol Lab Chiller Unit

Henan Lanphan Industry Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Glycol Lab Chiller Unit

Place of Origin : Henan, China

Brand Name : Lanphan

Certification : CE, ROHS

Supply Ability : 1000 Set/Sets per Month

Packaging Details : Packing of refrigerador industrial: carton or wooden case package, customized package is available.

MOQ : 1 - 2 Units

Price : $1,870.00

Applicable Industries : Manufacturing Plant, Food & Beverage Factory, Energy & Mining, Food & Beverage Shops

Condition : New

Type : Water-Cooled

Voltage : 220v

Dimension(L*W*H) : 660*515*990 mm

Weight : 60KG

Warranty : 1 YEAR

After-sales Service Provided : Video technical support, Online support

Power(W) : 1350

lowest no-load temperature : -30℃

best temperature range : ≤25℃

Environmental relative humidity : ≤70%

temperature display mode : liquid crystal

temperature stability : ±2℃

Sensor index : Pt100

Instrument adjusting range : ±150℃

Total machine power : 1350

Name : refrigerador industrial

refrigerant : R404A

Port : Shanghai, Tianjin, Qingdao

Contact Now

Glycol Low Temperature Chiller Compressor Refrigerador Industrial

The capacity of our refrigeration pump can be 5L-500L
Temperature ranges from room temperature to -120 degrees

Product Description

Glycol Lab Chiller Unit

DLSB low temperature pump adopts mechanical refrigeration low temperature circulating equipment and provides constant current and constant voltage circulating liquid to meet the requirement of the decreasing instrument (electric microscope, electricity probe,x-ray machine,laser reactor and accelerator) so as to guarantee the required working temperature.

The machine is essential to make sure the normal working condition for the device adopting constant current and constant pressure to cool in the condition of water scarcity ,poor quality of water and higher temperature. It can provide low temperature liquid to have multiple function of chemical reaction and medicine storage collocated with rotary evaporator, vacuum drying oven, circulating water multiple pump, magnetic force stirrer. It is especially used for different kinds of chemical biology ,physical lab which needed low temperature. It is the essential lab instrument for pharmacy, food industry, metallurgical industry and college scientific research.

Glycol Lab Chiller Unit

Type DLSB 20L-30°C
Tank volume (L) 24.38
lowest no-load temperature(°C) -30
Using temperature range (°C) room temperature—-30
best temperature range(°C) ≤25
Environmental relative humidity (%) ≤70
Working power supply (V/HZ) single phase220/50
temperature display mode liquid crystal
temperature stability(°C) ±2
Sensor index Pt100
Instrument adjusting range (°C) ±150
set way Arbitrary adjustment of Settings in the range of use
safety protection delay,leakage,over current,over heat
10°C 1845
0°C 1476
Output refrigerating capacity(w) -10°C 984
-20°C 615
-30°C 246
Total machine power (W) 1350
Machine current (A) 7.2
refrigerant R404A
circulating pump power(w) 100
flow rate(L/min) 20
lift(m) 6
external loop interface(mm) 14
opening size(mm) 260L×260
tank shape square
internal diameter and height of liquid storage tank(mm) 290×290×290
overall appearance size(mm) 565×460×845
machine weight(kg) 60
fuse 15A

Glycol Lab Chiller UnitGlycol Lab Chiller Unit

Turn on and off:
The right turn to turn on the machine: Add the appropriate refrigerating medium—connect the power with the special power supply—turn off the circulation switch—press the power button—open the circulation switch—open the refrigerator switch—open the cooling equipment
The right turn to turn off the machine.Turn off the cooling equipment—turn off the refrigerator switch—turn off the circulation switch(stirring switch)—turn off the outlet valve(or discharge the cooling medium)—turn off the power supply —disconnect circuit breaker—disconnect the power line from the power supply—clean the equipment.
Corollary Equipment

Glycol Lab Chiller Unit

Related Products

Glycol Lab Chiller UnitGlycol Lab Chiller Unit

The capacity of our refrigeration pump can be 5L-500L
Temperature ranges from room temperature to -120 degrees

Company Information
Glycol Lab Chiller Unit

Glycol Lab Chiller UnitGlycol Lab Chiller Unit

Glycol Lab Chiller Unit

Glycol Lab Chiller Unit

Glycol Lab Chiller Unit Contact us For more details about price, packing, shipping and discount. Tel: 86-371-67447999
Web: http://www.rotovap.cn
Address: Jianshe Road, Zhongyuan District, Zhengzhou, Henan, China


Product Tags:

Glycol Lab Chiller Unit

      

1350w Lab Chiller Unit

      

220v Lab Chiller Unit

      
Quality Glycol Lab Chiller Unit for sale

Glycol Lab Chiller Unit Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Henan Lanphan Industry Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)